Code: ETOPM10447
activated sludge unit.
[1] biological wastewater treatment. [2] aeration tank with 3 stirring machines
[3] secondary clarifier. [4] nitrification and pre-denitrification
[5] separate supply unit with 2 stirring machines.[6] all relevant flow rates adjustable
[7] control of temperature, pH value and oxygen concentration
[8] measurement of flow rate, temperature, pH value and oxygen concentration
[9] software with display of the operation states and data acquisition via USB under Windows Vista or Windows 7. [10] visual inspection with webcam on PC
Technical Data
Aeration tank - capacity nitrification zone: approx. 34L, - capacity denitrification zone: approx. 17L
Tanks - secondary clarifier: 30L, - raw water tank: 200L, - treated water tank: 80L
Flow rates - raw water pump: max. 25L/h,- return sludge pump: max. 25L/h, - circulation pump: max. 25L/h
Speeds (stirring machines) - secondary clarifier: max. 45min-1, - all others: each max. 600min-1
Measuring ranges - flow rate (raw water): 2...25L/h, - flow rate (compressed air): 50...550L/h, - temperature: 0...40°C
- pH value: 0...14, - oxygen concentration: 0...10mg/L
Dimensions and Weight LxWxH: 1550x790x1150mm (supply unit), LxWxH: 2830x790x1900mm (trainer)
Supplied with THEORETICAL – EXPERIMENTAL HANDBOOK