Code: MOT-CEM-0021
Automatic Vicat Test Apparatus.
The Automatic Vicat Test Apparatus (VICATRONX) is used for the
determination of the setting time and consistency of cement by Vicat
Method. The entire test is automatically gives precise and repeatable
results. Results are recorded on a built-in printer. This can eliminate
graph paper loading and reset requirements of the cylinder. Automatic
Vicat apparatus Tallinn to use, easy menus in several languages has
become easy.
Display:
Large, very bright and high-resolution LCD display, test data can be
seen by the general functions simultaneously. Test charts can be
displayed in real time, it is to replace the boot process with a pencil
on paper. The clock and calendar device to program the test loop is also
available.
Software:
Device, EN 196/3, AST C191 is programmed to automatically done the test
to be performed according to AASHTO T131 standards. special menus
available in the original software “free tests - free experiments” using
improved more programs. This feature is very useful for advanced and
flexible experiments on new charges and additives.
Timer 0 - 999 minutes. The software allows programming of the delay time
before starting the experiment. This feature, when mortar approximate
freezing time between known and to get a better measurement results to
set the frequency of penetration short period of time is useful when
prompted.
Probes:
Mobile penultimate weight of 300 g (1000 g to EN standards), and the
penetration of the needle 1.13 mm (1 mm to ASTM standard) and the
diameter can be programmed to free fall or guided fall.
possible total flexibility in timing. Penetration times over the course
of freezing securing changes penetration, from 0.5 minutes to 999
minutes (constant interval between the two penetration) or automatically
changed to 5 different phases at different intervals during the test.
Two options described above may be combined. Penetration measuring
accuracy of 0.1 mm with sensitive updates can be read by means of an
encoder.
Automatic Vicat device also calculates the following displays and writes
• Operator tarafınca determined after the sample separation time
• Test start time
• When the remaining time for the next penetration
• Test the end of the rest period
• The number of penetration Made
• The number of penetration to do
Test results:
All the parameters and results in memory together with the complete test results may be more than 50.
During the test, even for a very short time, any electrical device stops
automatically in case of interruption, the test is aborted and the data
obtained so far maintained.
Assay device automatically writes a report at the end of each
penetration value in this report shows the time and penetration number
of graphics.
The standard format of a separate printer or a USB port in order to connect to the HP protocol is available.