Code: MOT-EML-0003
Complete Training System for 3â€Phase Machines.
with training and installation
Each system must be composed minimally by the following components:
Squirrel Cage Motor 400/690/0.3
Threeâ€phase asynchronous motor with squirrel cage rotor and distinctive pullâ€out torque.
Ratings:
†Power: 0.27 kW
†Voltage: 400/690 V Δ/Y
†Current: 1.0/0.58 A
†Frequency: 50 Hz
†Power factor: 0.7
†Design: 4 pole
†Speed: 1350 minâ€1
Squirrel Cage Motor 230/400 V
Ratings:
†Power: 0.25kW
†Voltage: 400 /230V Y / Δ
†Current: 0.76 /1.32 A
†Frequency: 50 Hz
†Power factor: 0.79
†Design: 4 pole
†Speed: 1350 min â€1
Slip Ring Motor
Threeâ€phase asynchronous motor with slip ring rotor. Thermal protection required! Ratings:
†Power: 0.27 kW
†Voltage: 230/400 V Δ/Y
†Current: 2/1.16 A
†Frequency: 50 Hz
†Power factor: 0.72
†Design: 4 pole
†Speed: 1340 minâ€1
Multiâ€Function Machine
Ratings for operation as slip ring motor:
†Power: 0.27 kW
†Voltage: 230/400 V Δ/Y
†Current: 1.44/0.83 A
†Frequency: 50 Hz
†Power factor: 0.7
†Design: 4 pole
Ratings for operation as synchronous motor
†Speed: 1360 minâ€1
†Power: 0.27 kW
†Voltage: 230/400 V Δ/Y
†Current: 0.9/0.52 A
†Excitation voltage: 20 V
†Excitation current: 4 A
†Frequency: 50 Hz
†Power factor: 1
†Design: 4 pole
†Speed: 1500 minâ€1
Two speed Squirrel Cage Motor
Threeâ€phase asynchronous motor with squirrel cage rotor, pole changeable.
Ratings:
†Power: 0.25/0.37 kW
†Voltage: 400 V Δ/Yâ€Y
†Current: 1.0/1.1 A
†Frequency: 50 Hz
†Power factor: 0.62/0.75
†Design: 4/2 pole
†Speed: 1400/2800 minâ€1
Squirrel Cage Motor
Threeâ€phase asynchronous motor with squirrel cage rotor, 2 separate windings, pole
changeable. Ratings:
†Power: 0.11/0.20 kW
†Voltage: 400 V Y/Y
†Current: 0.6/0.7 A
†Frequency: 50 Hz
†Power factor: 0.71/0.72
†Design: 6/2 pole
†Speed: 880/1390 minâ€1
Synchronous Machine
Threeâ€phase synchronous machine with salient pole rotor and damper cage for motor and
generator operation.
†Power: 0.3 kW
†Voltage: 400 V Y
†Current: 0.43 A
†Excitation voltage: max.140 V
†Excitation current: max.0.55 A
†Frequency: 50 Hz
†Power factor: 1/0.8
†Design: 4 pole
†Speed: 1500 minâ€1
Synchronous Machine
Threeâ€phase synchronous machine with smoothâ€core rotor and damper cage for motor and
generator operation.
†Power: 0.3 kW
†Voltage: 230/400 V Δ/Y
†Current: 0.66/1.14 A
†Excitation voltage: max.150 V
†Excitation current: max.0.95 A
†Frequency: 50 Hz
†Power factor: 0.97
†Design: 4 pole
†Speed: 1500 minâ€1
Machine Test System
Software for recording the characteristics of Electrical Machines
Data Acquisition system with software
Threeâ€Phase Supply Unit with full control
To switch the 3â€phase supply in experiments with electrical loads for line voltages of 400
V.
†Cam switch 4 pole
†Fault current circuit breaker 30 mA
†Motor protection switch 6â€10 A
†Phase control lamps L1, L2, L3
Excitation Voltage Controller 200V/2,5 A
Adjustable power supply with smoothed current and voltage for supplying power to a
synchronous machine in the power class 0.3 kW or 1.0 kW.
†Output voltage U: 0...200 V
†Output current I: max. 2,5 A
†The output is overloadâ€proof and shortâ€circuitâ€proof.
†Supply voltage: 230 V, 50/60 Hz
Motor Protection Switch 1â€1.6A
Threeâ€pole, with overload and instantaneous shortâ€circuit trip, singleâ€phasing sensitivity
according to
†Bimetal tripping, setting range: 1.0 †1.6 A
Resistive Load
Three synchronously adjustable rheostats (Step winding) with scale 100 †0 %,
each with a series resistor and fuse in theslidingâ€contact connection, suitable for
parallel, series, star and delta circuits.
Resistance: 3 x 1800 Ohm
Series resistance: 3 x 47 Ohm
Current: 3 x 1 A
Capacitive Load
Three groups of MP capacitors, each consisting of four capacitors, suitable for parallel, series,
star and delta circuits.
†Capacitance:
†3 x 1/2/4 μF, 450 V
†3 x 8 μF, 400 V
Inductive Load
Three inductances with taps at 0.2/0.4/0.6 H (0.65 A), 0.8/1.0/1.2 H (0.5 A) and 2.4/4.8/6.0 H
(0.25 A) suitable for parallel, series, star and delta circuits.
Manual Synchronization Unit
Synchronization unit with manual switch to connect the generator to the mains.Equipped with:
†two 7â€segment voltage displays
†two 7â€segment frequency displays
†one 7â€segment Zeroâ€volt display
†one optical synchronoscope
†six synchronization lamps
†two control up/down indicators for voltage and frequency
†two direction indicators of the rotating field
†one manual three pole switch
On/Off Switch Threeâ€Pole
For switching of threeâ€phase units.
†Switch load: 20 A / 500 V AC
†Switch positions: 0 †1
Power Circuit Breaker Module
3â€phase ON/OFF switch with auxiliary contact (NC) for transmission line model 380 kV. Can be
controlled manually using ON/OFF pushbutton or externally via switching contact, TTL level or
24 V DC. The switching state is indicated by LED's and is additionally available as TTL level from
4â€mm sockets. Control input (switching contact, TTL level, 24 V DC) for external switchâ€off
command (tripping on faults).
†Contact load capacity: 400 V AC, 3 A
†Mains connection: 115/230 V, 50 Hz with mains connecting cable and earthingâ€pin plug
Starâ€delta switch
To start induction machines.Technical data
†Switch load: 20 A / 500 V AC
†Switch positions: 0 †Y †Δ
Starâ€Delta Reversing Switch
†Switch load: 20 A / 500 V AC
†Switch positions: Δ â€ Y †0 †Y †Δ
Reversing Switch
†Switch load: 20 A / 500 V AC
†Switch positions: 1 †0 †2
Star Delta Starter
Contactor group with time relays for starting threeâ€phase motors of up to approx. 1,5 kW.
On/off switching is carried out via two pushbuttons I and 0. Automatic switchover from star to
delta is carried out after the preset time elapses.
The momentary operating status signal lamps.
†Switching capacity: 1.5 kW
†Switchover time delay: 0.3...30 s
†Supply voltage: 3 x 400 V AC
Soft starter 0.3/1.0
3~ soft control device for asynchronous machines with control input and set possibilities for:
â€Start ramps time
â€Start tension
â€Stop ramps time
Rotor Starter
Three resistors, synchronously adjustable in 6 steps, for slip ring motor and multifunction
machine 0.3 kW.
†Resistance values of switch steps: 20/10/5.5/2.5/1/0 Ohm
†Additional fixed taps at: 10/2.5 Ohm
Pole Reverser Dahlander
†Switch load: 20 A / 500 V AC
†Switch positions: 0 †1 †2
Pole Reverser Sep. Windings
†Switch load: 20 A / 500 V AC
†Switch positions: 0 †1 †2
Blocking Gear Mechanism 0.1/0.3
Hand operated gear mechanism for setting the rotor of a threeâ€phase asynchronous motor with
slip ring rotor 0.1/0.3 kW when used as a phase shifting transformer.
†n2 = 1, n1 = 20
Fault Simulating. Squirrel Cage
The fault simulator in conjunction with the squirrelâ€cage motors in the 0,3 kW and 1,0 kW
power classes permits the simulation of typical malfunctions like:†Short to ground
†Winding breaks
†Turnâ€toâ€turn faults
†Windingâ€toâ€frame shortâ€circuit
†Tripping the thermal circuit breakerThe faults are generated by 13 switches arranged behind a
locked cover.
Coupling 0.1/0.3
Rubber coupling sleeve for mechanical connection of two electrical machines of the 0.1 or 0.3
kW series.
Multimeter
Features:
†Automatic socket blocking to prevent plugging of leads into the wrong sockets
†Automatic and manual battery cutâ€out
†Warnings for fuse breaks and overloads
†Automatic and manual range selection
†True effective value measurement: TRMS
†Automatic scaling of the analog display
†EMCâ€compliant design
†Set of safety leads
Technical data:
†DC voltage ranges: 100 mV ... 1000 V
†AC voltage ranges: 100 mV ... 1000 V
†DC current ranges 1 A ... 10 A
†AC current ranges: 1 A ... 10 A
†Resistance measuring ranges: 100 Ω... 40 MΩ
†Frequency: 100 Hz .... 30 kHz
†Temperature: †250 °C ... +1372 °C
†Resolution: 10 μV; 100 μA; 10 mΩ; 0.01 Hz; 0.1 °C
†Continuity/diode test: yes
Power factor meter
Demonstration meter for power factor (cos phi) and phaseâ€angle.
Measurement ranges:
Power factor: 0...1...0
Phase angle: â€90°(cap.)†0 †+90°(ind.)
Voltage range: 3...1000 V, Ri = 1 MΩ
Current range: 0.1...30 A, Ri = 10 mΩ
Frequency range: 20 Hz... 2 kHz
Insulation Tester
Battery operated insulation tester as per VDE 0413, Part 1 for testing equipment and systems
up to 500 V voltage rating.
†Measurement ranges:
†Insulating resistance:
†0..500 kOhm
†0.4..20 MOhm
†Resistance: 0...1000 Ohm (U0 appr. 370 V DC) with fast beeper testing
†Voltage: 0...500 V AC/DC
†For insulation testing:
†Voltage rating: 500 V
†Current rating: 1.06 mA
Moving Iron Meter 2.5 A
†Moving iron ammeter.
†Front frame: 144 x 144 mm
†Measurement ranges: 0 †2.5 A
Moving Iron Meter 600 V
Moving iron voltage meter.
Front frame: 144 x 144 mm
Measurement ranges: 0 †600 V
RMS Meter
Demonstration meter for measuring the true RMS voltages and currents.
†Types of measurement:
†RMS †AC + DC total true RMS
†RMS †AC alternating true RMS
†AV †AC + DC arithmetic average valueSwitchover is possible for all ranges
Multifunctional measuring instrument
Set of 10 32 A safety bridging plugs, black
Safety Bridging Plugs with Tap, black, set of 10
Safety bridging plugs, yellow/green, set of 10
Safety connecting leads, 32 A, it contain:â€
2 each safety connecting lead, red 100 cm
2 each safety connecting lead, blue 100 cm
2 each safety connecting lead, red 50 cm
2 each safety connecting lead, blue 50 cm
2 each safety connecting lead, red 25 cm
2 each safety connecting lead, blue 25 cm
4 each safety connecting lead, black 100 cm
6 each safety connecting lead, black 50 cm
6 each safety connecting lead, black 25 cm
4 each safety connecting lead, black 10 cm
Safety connecting lead 32 A, yellow/green, set of 10
Mobile cable holder
Mobile Experiment Stand,
experimental manual Asynchronous Machines and Synchronous Machines
Software to manage experimental manuals and user interface