Code: MOT-EML-0002
Complete Training System for Single Phase AC Machines.
with training and installation
Each system must be composed minimally by the following components:
Universal Motor with protection
For operation with 220 V AC or DC .Ratings for connection to AC.
†Power: 0.2 kW
†Voltage: 230 V AC case
Voltage: 140 V DC case
†Current: 2.5 A AC case
†Current: 3 A DC case
†Frequency: 50 Hz
Capacitor Motor
Singleâ€phase AC motor with starting relay,
Capacitor Starting and run
Ratings:
†Power: 0.37 kW
†Voltage: 230 V
†Current: 2.6 A
†Frequency: 50 Hz
†Design: 4 pole
†Speed: 1400 minâ€1
Capacitor Motor
Singleâ€phase AC motor with centrifugal switch,Capacitor Starting and run
Ratings:
†Power: 0.25 kW
†Voltage: 230 V
†Current: 2.2 A
†Frequency: 50 Hz
†Power factor: 0.85
†Design: 4 pole
†Speed: 1420 min‹
Motor Protection Switch 1â€1.6A
Threeâ€pole, with overload and instantaneous shortâ€circuit trip, singleâ€phasing sensitivity
according to.
†Bimetal tripping, setting range: 1.0 †1.6 A
Motor Protection Switch 1.6â€2.4A
Threeâ€pole, with overload and instantaneous shortâ€circuit trip, singleâ€phasing sensitivity
according to
†Bimetal tripping, setting range: 1.6 †2.4 A
On/Off Switch Threeâ€Pole
Power Circuit Breaker Module
3â€phase ON/OFF switch with auxiliary contact (NC) for transmission line model 380 kV.
Can be controlled manually using ON/OFF pushbutton or externally via switching contact, TTL
level or 24 V DC.
The switching state is indicated by LED's and is additionally available as TTL level from 4â€mm
sockets. Control input (switching contact, TTL level, 24 V DC) for external switchâ€off command
(tripping on faults).
†Contact load capacity: 400 V AC, 3 A
†Mains connection: 115/230 V, 50 Hz with mains connecting cable and earthingâ€pin plug
Machine Test System
Equipment set for recording the characteristicsof electrical machines.
Software for recording the characteristics of Electrical Machines
Multimeter
Features:
†Automatic socket blocking to prevent plugging of leads into the wrong sockets
†Automatic and manual battery cutâ€out
†Warnings for fuse breaks and overloads
†Automatic and manual range selection
†True effective value measurement: TRMS
†DC voltage ranges: 100 mV ... 1000 V
†AC voltage ranges: 100 mV ... 1000 V
†DC current ranges 1 A ... 10 A
†AC current ranges: 1 A ... 10 A
†Resistance measuring ranges: 100 Ω... 40 MΩ
†Frequency: 100 Hz .... 30 kHz
†Temperature: †250 °C ... +1372 °C
†Resolution: 10 μV; 100 μA; 10 mΩ; 0.01 Hz; 0.1 °C
†Continuity/diode test: yes
†TRMS: AC and AC+DC, 10 kHz
†Fundamental error, V DC: 0.05 % of measured value / ± 3 digits
Power factor meter
Adjustable transformer 0...260 V, 4 A
Moving Iron Meter 2.5 A
†Measurement ranges: 0 †2.5 A
Moving Iron Meter 100/400 V
Set of 10 32 A safety bridging plugs, black
Safety Bridging Plugs with Tap, black, set of 10
Safety bridging plugs, yellow/green, set of 10
Safety connecting leads, 32 A, it contain:â€
2 each safety connecting lead, red 100 cm
2 each safety connecting lead, blue 100 cm
2 each safety connecting lead, red 50 cm
2 each safety connecting lead, blue 50 cm
2 each safety connecting lead, red 25 cm
2 each safety connecting lead, blue 25 cm
4 each safety connecting lead, black 100 cm
6 each safety connecting lead, black 50 cm
6 each safety connecting lead, black 25 cm
4 each safety connecting lead, black 10 cm
Safety connecting lead 32 A, yellow/green, set of 10
Mobile cable holder
Mobile Experiment Stand,
manual of 1P AC Machines (in English)
Required Software to manage experimental manuals and interface