Code: ETOPM10435
FILTRATION PILOT PLANT.
INTRODUCTION
This fi ltration plant mainly consists of a sand fi lter and of an
activated carbon fi lter; fi ltered water is collected into a tank
of stainless steel from which samples for proper laboratory
analyses can be extracted. An in-line turbidimeter enables to
measure the turbidity of water fl owing in and out of fi lters.
Process control, data acquisition and supervision are
automatically carried out by a microprocessor controller and
by a specifi c control and supervision software
that enables the remote control of various operational
Parameters
TRAINING PROGRAM:
The process unit enables to develop and analyze the following
issues:
• mechanical filtration
• chemical fi ltration
• main parameters affecting fi ltration
• infl uence of feed fl ow rate on fi ltration
• automatic PID control
• plant supervision (only for
TECHNICAL CHARACTERISTICS:
• Framework of AISI 304 stainless steel with castors
• Sand fi lter of borosilicate glass with decresing particle size
and capacity of 30 l
• Activated carbon fi lter of borosilicate glass with capacity
of 30 l
• 4 pressure gauges, with range of 0 to 10 m of water column
• Centrifugal pump with casing and rotor of AISI 304 stainless
steel and fl ow-rate of 3000 l/h
• Variable area fl owmeter of AISI 304 stainless steel, with
range of 100 to 1000 l/h
• Metering pump of plastic material for sodium hypochlorite,
with fl ow rate of 3 l/h
• Metering pump of plastic material for fl occulant, with
fl ow-rate of 3 l/h
• 2 feed tanks of AISI 304 stainless steel with capacity of 120 l
• Tank of AISI 304 stainless steel for collecting the fi ltered
water with capacity of 200 l
• Thermoresistance Pt 100 with sheath of AISI 316 stainless steel
• Board-type electronic temperature indicator
• Switchboard IP55, complying with EC conformity mark, including plant synoptic and ELCB
• Connecting lines and valves of AISI 304 and 316 stainless Steel
• Pneumatic control valve of stainless steel AISI 316 for feed fl ow rate of water, Cv = 2.5
• Electropneumatic converter (4 to 20 A / 0.2 to 1 bar)
• Electronic turbidimeter for measuring the turbidity of the
water fl owing in and out of fi lters, with programmable range and 4 to 20 mA output signal
• Digital microprocessor PID controller, with two control loops
• Supervision software for Windows: it enables to control ONOFF signals, analog signals coming from PID controller, realtime
trend and historical trend
Power supply: 230 Vac 50 Hz single-phase - 1,5 kVA
(Other voltage and frequency under request)
Dimensions: 2150 x 750 x 2000 mm
Weight: 460 kg
Supplied THEORETICAL – PRACTICAL – EXPERIMENTAL HANDBOOK