GC/MS.
Computer controlled, high performance, fully integrated bench top quadruple GC/MS including, Clarus 500 gas Chromatograph mass Spectrophotometer with FID; Trace GC with split/splitters capillary injector with independent septum purge and split valve programming. Digital pressure and flow control. Multi temperature ramp programmable, oven maximum temperature 450ºC built-in soft ware for remote diagnostics. Temperature range from few degrees above ambient to 450ºC. Program rates 0.1 to 120 º C/min through seven ramps. Typical cool down time 450º C to 50º C in 250s. Typical heat time 50ºC to 450ºC in 420 s. Digital pressure flow contr Key board/user interface, optimized geometry/split/splitters injector, GC/MS interface, reference inlet, . Electron impact ion source, quadruple analyzer, photomultiplier detector, real time peak display, vacuum system, data system hardware, data system soft ware, open access GC/MS software, large volume BEST PTV injector, base body with DGFC for FID (with make up).
Detectors:- Flame ionization detector (FID)
Columns; to be provided with test chemicals to check their performance
3X general purpose packed column (polar Column)
3X general purpose packed column (non polar)
3X analytical packed columns (polar)
3X analytical packed columns (non polar)
2 ml screw top vials, complete with plastic screw caps and septa (set of 100)
Injector; with on column and large volume injection capabilities
Start up Kit; -
Injection volume in 0.1 µ/steps
Filling speed from 1 to 100 µl/s
Needle dwell time 0 to 63 seconds
- 2 soap bubble flow meters (5 and 50 cc/min)
- Intermediate fittings
- T and cross shaped rubber and metal tubing with relative fittings
- 10 µ capacity syringe , 70 mm length fixed needle for split less operation
- Auto sampler suitable for capillary column vaporizing injectors, packed column injector, and true cold on-column injector
- Injection volume in 0.1 µ/steps
Injector speed from 1 to 100 µl/s
Filling speed from 1 to 100 µl/s
- Needle dwell time 0 to 63 seconds
The auto sampler is supplied with:-
Go position sample tray --two micro syringes 10 µl, capacity 88 mm length fixed needle fixed needle, which is suitable for on column split and split less injection techniques, and 10 µl capacity, 50 mm length needle, suitable for split injection technique.
2 ml screw top vials, complete with plastic screw caps and septa (set of 100)
plastic spacer for 2 ml screw top vials (set of 100)
GC/MS, India, Manufacturers, Suppliers, Exporters
- 1/8 Inch blanking Nut X1
-1/8 Inch Interface ferrule X!
- Fine point Tweezers X
- Column cutter X1
- Loop Back Socket X1
-Heptacosa 1 gm
-Jubilee clips X4
- El+ source alignment X1
-Source heater assembly X1
- Loop back connector X1
-source filaments X2
-Fiber Glass pencil X1
- The following additional parts may be used by the engineer the installation
-GC column (15 m, 0.25 mm id x 0.25 um)
-Septa 5 x restek
-Leners 2 x restek
- 4 x ferrules for 4 mm tubing
-4 x ferrules for 2 mm tubing
- 2 X nuts for 4 mm tubing
-4 mm – 2mm reducer
OPTIONAL
Water chiller/circulator if lab temperature >2ºC (Water Cooling Kit required if trace MS is to be water cooled, factory fit only)
Installation, testing, commissioning and instrument training by qualified engineer during commissioning is required. Supplied with a complete set of operation and maintenance manuals.