Code: ETOPM10312
Losses in a Pipe System.
Specification
[1] investigation of pressure losses in piping elements and shut-off devices
[2] different measuring objects for determining flow rate according to the differential pressure method
[3] six pipe sections capable of being individually shut off, with different piping elements: sudden contraction, sudden enlargement, Y-pieces, T-pieces, corners and bends
[4] one pipe section to hold interchangeable shut-off/measuring objects
[5] measuring objects made of transparent material: Venturi nozzle, orifice plate flow meter and measuring nozzle
[6] shut-off devices: angle seat valve, gate valve
[7] annular chambers allow measurement of pressure without interaction
[8] 2 twin tube manometers for measuring the pressure difference
[9] flow rate determined base module
[10] water supply via laboratory supply
Technical Data
Pipe section to hold fittings or measuring objects - 20x1,5mm, PVC
Pipe sections Inside diameter: d, - straight: d=20x1,5mm, length: 800mm, PVC, - sudden contraction: d=32x1,8-20x1,5mm, PVC, - sudden enlargement: d=20x1,5-32x1,8mm, PVC, - with 2x Y-piece 45° and 2x T-piece, - with 2x 90° elbow/bend: d=20x1,5mm, PVC and
2x 45° elbow: d=20x1,5mm, PVC, 2x twin tube manometers: 0...1000mmWC
Measuring range - pressure: 0...0,1bar
Dimensions and Weight LxWxH: 1550x640x1300mm, Weight: approx. 58kg
Supplied with THEORETICAL – EXPERIMENTAL HANDBOOK