Code: MOT-COM-0005
3000 kn Automatic Compression Testing Machine with 200 kn Flexural Fra.
compression testing machines have been manufactured for consistent
testing of concrete cube and cylinder specimens. These machines are
produced to capacity range of 3000 kN . Suitable for CE security norms
and ASTM C39, EN 12390-3, 12390-4, BS 1881, AASHTO 22 to standards.
The suitable vertical clearance for specimen can be adjusted with
distance pieces. all model compression machines calibration values are
within class 1 starting from 50 kN.
Surface hardness 55HRC, flatness tolerance 0.02 mm. Traceable
certificate of surface hardness available on request. 110 V, 50 Hz
models are available. The only difference is the input voltage.
200 kN capacity Flexural Frame:
200 kN capacity flexure frame have been designed for reliable and
consist ent testing of fl exural test on standard concrete beams,
concrete or natural stone kerbs, concrete paving fl ags, and natural
stone slabs and tensile splitting test of concrete paving blocks. The
flexure testing frame is the result of con tinuous research to upgrade
the testing machines with latest technologies to conform to the latest
standards EN 12390-5, EN 12390- 6, EN 1338, EN 1340, BS 1881, ASTM C78,
C293 and C496 in terms of its technical properties taking into account
client requirements. These also meet the requirements of CE norms for
health and safety of the operator.
Automatic Control Unit
The automatic hyraulic power pack is have control valve. Automatic
hyraulic power pack is can do control the two frames with this control
valve. Tests can be performed by either on TMC304 Unit or on a computer
with using free software. The advantages of performing tests on computer
with using software, such as reporting, graphical output, etc. Setting
test parameters, including pace rate only required when the specimen
type is changed. Pressing the START button on the control unit.
The machine automatically starts the rapid approach; switches the test
speed after 1% of the load capacity of the machine and stops once the
specimen failure. Automatically saves the test parameters and test
results.
The range of Flexural Machines have the accuracy of Class 1 start ing
from 2% of the full capacity. Flextural test assemblies should be
ordered seperately.