Code: NJU-17-0275
COMPLETE TRAINING SYSTEM FOR ELECTRICAL POWER OPERATION.
with installation and training
Complete system for training in electrical power system operation, covering minimally the following laboratory experiments:
Automatic synchronization circuit
-Generator Cos Phi Control
-Automatic generator active power control
-Generator Fed Transmission System with RLC Loads
-Reactive power compensation, panel system
-Experiments with the parallel switching device
-Experiments on active power control
-Experiments on reactive power control (cos φ- control)
-Reactive power compensation at different loads
-Experiment on automatic speed control
-Performance characteristics of generator and transmission line at various load types
-Performance characteristics of generator and transmission line at higher frequency
Each system must be composed minimally by the following components:
 Synchronization Unit
 Automatic Synchronizer
• Microcontroller-based
 Manual Synchronization Unit
 Reactive Power Controller
• Electronic VAr controller.
• Compensation range: 0.8 ind...1...0.8 cap
• Switch manual/automatic
• Supply voltage: 3 x 380...415 V, 50/60 Hz
 Voltage Controller
 Active Power Controller
 Generator Cos Phi Controller
 Power Circuit Breaker Module
 Adjustable Resistive Load
- Resistance: 3 x 1000 Ohm
- Series resistance: 3 x 22 Ohm
- Current: 3 x 2.5 A
 4 switching levels Switchable Capacitor bank
Capacitance values:
Switching level 1: 3 x 2 µF, 450 V, 50 Hz
Switching level 2: 3 x 4 µF, 450 V, 50 Hz
Switching level 3: 3 x 8 µF, 400 V, 50 Hz
Switching level 4: 3 x 16 µF, 400 V, 50 Hz
Compensation power: max. 1368 VAr
 Three-Phase Supply Unit with Fault current circuit breaker (FCCB)
 Excitation Voltage Controller 200V/2,5 A
- Output voltage U: 0...200 V
- Output current I: max. 2,5 A
- Supply voltage: 230 V, 50/60 Hz
 Data Acquisition system with software
Three-Phase Transformer TL 380KV
Transformer for feeding the transmission line model 380 kV.
Scale factor 1:1000 for secondary current and voltage.
Rated power: 800 VA
Primary: 3 x 400 V winding with tapping at 230 V, can be switched to star or delta connection.
Delta stabilizing winding can be connected.
Secondary: 3 x 380 V winding with tapings at
+ 5 %, - 5 %, - 10 %, - 15 % in star connection, various star point connections possible
 Transmission Line Model 400 kV or 230 kV
Three-phase model of a 400 kV or 230 kV overhead transmission line
Specifications:
Quad bundle 240/40,
Surge impedance 240 Ohm and
Natural power 600 MW
Software for control at distance
Excitation Voltage Controller 200V/2,5 A
Machine test system 1.0 KW
Synchronous Machine SC 1.0
Three-phase
synchronous machine with smooth core rotor and damper cage for motor
and generator operation. Temperature protection required! Ratings for
motor operation:
- Power: 0.8 kVA
- Voltage: 230/400 V Δ/Y
- Current: 2.66/1.52 A
- Excitation voltage: max.220 V
- Excitation current: max.1.6 A
- Frequency: 50 Hz
- Power factor: 0.8-1-0.8
- Design: 4 pole
- Speed: 1500 min-1
Power meter
Power factor meter
Moving Iron ammeter. Meter 2.5 A
- Measurement ranges: 0 - 2.5 A
Moving Iron voltage meter 100/400 V
- 0 - 400 V
- 0 - 100 V
RMS Meter
Incremental Tacho 1.0
Multifunctional measuring instrument
 Set of 10 32 A safety bridging plugs, black
 Safety Bridging Plugs with Tap, black, set of 10
 Safety bridging plugs, yellow/green, set of 10
 Safety connecting leads, 32 A, it contain:-
• 2 each safety connecting lead, red 100 cm
• 2 each safety connecting lead, blue 100 cm
• 2 each safety connecting lead, red 50 cm
• 2 each safety connecting lead, blue 50 cm
• 2 each safety connecting lead, red 25 cm
• 2 each safety connecting lead, blue 25 cm
• 4 each safety connecting lead, black 100 cm
• 6 each safety connecting lead, black 50 cm
• 6 each safety connecting lead, black 25 cm
• 4 each safety connecting lead, black 10 cm
 Safety connecting lead 32 A, yellow/green, set of 10
 Mobile cable holder
 Mobile Experiment Stand,
 Equipment board for experiment stand
 Required PC Software for manage experimental manuals and user interface for convenient viewing and all necessary accessory
 Experiment manual of
• Power Station Control
• Reactive Power Compensation of an Inductive Load
Generator-Fed Transmission system with RLC-Load