Code: NJU-17-0115
COMPLETE TRAINING SYSTEM FOR SINGLE PHASE AC MACHINES.
COMPLETE TRAINING SYSTEM FOR SINGLE PHASE AC MACHINES with training and installation
Each system must be composed minimally by the following components:
 Universal Motor with protection
For operation with 220 V AC or DC .Ratings for connection to AC.
- Power: 0.2 kW
- Voltage: 230 V AC case
Voltage: 140 V DC case
- Current: 2.5 A AC case
- Current: 3 A DC case
- Frequency: 50 Hz
 Capacitor Motor
Single-phase AC motor with starting relay,
Capacitor Starting and run
Ratings:
- Power: 0.37 kW
- Voltage: 230 V
- Current: 2.6 A
- Frequency: 50 Hz
- Design: 4 pole
- Speed: 1400 min-1
 Capacitor Motor
Single-phase AC motor with centrifugal switch,Capacitor Starting and run
Ratings:
- Power: 0.25 kW
- Voltage: 230 V
- Current: 2.2 A
- Frequency: 50 Hz
- Power factor: 0.85
- Design: 4 pole
- Speed: 1420 min-¹
Motor Protection Switch 1-1.6A
Three-pole, with overload and instantaneous short-circuit trip, single-phasing sensitivity according to.
- Bimetal tripping, setting range: 1.0 - 1.6 A
Motor Protection Switch 1.6-2.4A
Three-pole, with overload and instantaneous short-circuit trip, single-phasing sensitivity according to
- Bimetal tripping, setting range: 1.6 - 2.4 A
On/Off Switch Three-Pole
Power Circuit Breaker Module
3-phase ON/OFF switch with auxiliary contact (NC) for transmission line model 380 kV.
Can be controlled manually using ON/OFF pushbutton or externally via switching contact, TTL level or 24 V DC.
The switching state is indicated by LED's and is additionally available as TTL level from 4-mm sockets. Control input (switching contact, TTL level, 24 V DC) for external switch-off command (tripping on faults).
- Contact load capacity: 400 V AC, 3 A
- Mains connection: 115/230 V, 50 Hz with mains connecting cable and earthing-pin plug
 Machine Test System
Equipment set for recording the characteristicsof electrical machines.
 Software for recording the characteristics of Electrical Machines
 Multimeter
Features:
- Automatic socket blocking to prevent plugging of leads into the wrong sockets
- Automatic and manual battery cut-out
- Warnings for fuse breaks and overloads
- Automatic and manual range selection
- True effective value measurement: TRMS
- DC voltage ranges: 100 mV ... 1000 V
- AC voltage ranges: 100 mV ... 1000 V
- DC current ranges 1 A ... 10 A
- AC current ranges: 1 A ... 10 A
- Resistance measuring ranges: 100 Ω... 40 MΩ
- Frequency: 100 Hz .... 30 kHz
- Temperature: - 250 °C ... +1372 °C
- Resolution: 10 µV; 100 µA; 10 mΩ; 0.01 Hz; 0.1 °C
- Continuity/diode test: yes
- TRMS: AC and AC+DC, 10 kHz
- Fundamental error, V DC: 0.05 % of measured value / ± 3 digits
 Power factor meter
 Adjustable transformer 0...260 V, 4 A
 Moving Iron Meter 2.5 A
- Measurement ranges: 0 - 2.5 A
 Moving Iron Meter 100/400 V
 Set of 10 32 A safety bridging plugs, black
 Safety Bridging Plugs with Tap, black, set of 10
 Safety bridging plugs, yellow/green, set of 10
 Safety connecting leads, 32 A, it contain:-
• 2 each safety connecting lead, red 100 cm
• 2 each safety connecting lead, blue 100 cm
• 2 each safety connecting lead, red 50 cm
• 2 each safety connecting lead, blue 50 cm
• 2 each safety connecting lead, red 25 cm
• 2 each safety connecting lead, blue 25 cm
• 4 each safety connecting lead, black 100 cm
• 6 each safety connecting lead, black 50 cm
• 6 each safety connecting lead, black 25 cm
• 4 each safety connecting lead, black 10 cm
 Safety connecting lead 32 A, yellow/green, set of 10
 Mobile cable holder
 Mobile Experiment Stand,
 manual of 1P AC Machines (in English)
Required Software to manage experimental manuals and interface