Code: NJU-17-0104
SET OF COMPLETE TRAINING SYSTEM.
(modules) for TRANSFORMER with training and installation
Each system (module) must be composed minimally by the following components:
 3-PH. Transformer
- Power: 300 VA
- Primary: 3 x 400/230 V, 50 Hz
- Secondary: 3 x 2 x 115 V
 Scott Transformer
For transforming from a two-phase to a three-phase mains and vice-versa using a Scott circuit. It can also be used as a three-phase isolating transformer for transformation of 3 x 115/230/400 V into 3 x 115/230 V and vice-versa.
- Power: 2 x 150 VA
- Primary: 2 x 115/200/230/346/400 V, 50 Hz
- Secondary: 2 x 115/230 V
 1-PH. Transformer
- Power: 300 VA
- Primary: 230 V, 50/60 Hz
- Secondary: 2 x 115 V
 AC-Toroidal Core Transformer
- Power: 300 VA
- Primary: 230 V, 50 Hz
- Secondary: 2 x 115 V
 AC-Auto Transformer
- Power: 300 VA
- Primary: 230 V, 50 Hz
- Secondary: 115/230/240 V
 Resistive Load
Three synchronously adjustable circularrheostats (Step winding) with scale 100 - 0 %,
each with a series resistor and fuse in thesliding-contact connection, suitable for
parallel, series, star and delta circuits.
-Resistance: 3 x 1800 Ohm
-Series resistance: 3 x 47 Ohm
-Current: 3 x 1 A
 Capacitive Load
Three groups of MP capacitors, each consisting of four capacitors, suitable for parallel, series, star and delta circuits
- Capacitance:
- 3 x 1/2/4 µF, 450 V
- 3 x 8 µF, 400 V
 Inductive Load
Three inductances with taps at 0.2/0.4/0.6 H (0.65 A), 0.8/1.0/1.2 H (0.5 A) and 2.4/4.8/6.0 H (0.25 A) suitable for parallel, series, star and delta circuits.
 Note All connections via safety sockets.
 Multimeter
Features:
- Automatic socket blocking to prevent plugging of leads into the wrong sockets
- Resolution: 10 µV; 100 µA; 10 mΩ; 0.01 Hz; 0.1 °C or more
 Power factor meter
Demonstration meter for power factor (cos phi) and phase-angle.
-Measurement ranges:
Power factor: 0...1...0
Phase angle: -90°(cap.)- 0 - +90°(ind.)
 Four Channel Isolation Amplifier
Four highly linear, crosstalk and noiseimmune isolating amplifiers for potentialfree measurement recording in static converter, drive and frequency converter technology used in conjunction with an oscilloscope or computer interface.
- Lowpass filter, switchable: 1 kHz- Mains connection: 115/230 V, 47...63 Hz with mains connection cable and Euro plug.
 Data Acquisition system with software
Data acquisition system with minimally the following specifications:
- 5 Analog inputs
- 12 Digital inputs (TTL)
- 1 USB-port for connection to a computer
- 1 data bus for connecting additional modules
- Windows XP/Vista/7/8/10 (32+64 bits
-Electrically isolated current measurement with data acquisition computer interface system
 Adjustable transformer 0...260 V, 4 A
- Mains voltage: 230 V, ± 10 %, 50...60 Hz
- Output: 1 x 260 V / 4 A AC
- Output: 2 4-mm safety sockets with connecting leads and shock-proof plug 16 A
 3-Phase Voltage 400 V/2.5 A Fault current circuit breaker (FCCB)
-mains switch: 4-pole cam switch
-mains voltage: 3 x 400 V ± 10 %, 50 - 60 Hz
-outputs: 3 x 0 - 400 V AC
 Set of 10 32 Asafety bridging plugs, black
 Safety Bridging Plugs with Tap, black, set of 10
 Safety bridging plugs, yellow/green, set of 10
 Safety connecting leads, 32 A, it contain:-
• 2 each safety connecting lead, red 100 cm
• 2 each safety connecting lead, blue 100 cm
• 2 each safety connecting lead, red 50 cm
• 2 each safety connecting lead, blue 50 cm
• 2 each safety connecting lead, red 25 cm
• 2 each safety connecting lead, blue 25 cm
• 4 each safety connecting lead, black 100 cm
• 6 each safety connecting lead, black 50 cm
• 6 each safety connecting lead, black 25 cm
• 4 each safety connecting lead, black 10 cm
 Safety connecting lead 32 A, yellow/green, set of 10
 Mobile cable holder
 Mobile Experiment Stand,
 Equipment board for experiment stand
 Experiment manual of Transformers
Required Software